Conduct a broad range of single specimen damper testing, ranging from characterization and in-line production quality to custom applications such as NVH, high-velocity testing and road profile playback. The MTS damper testing portfolio features a selection of compact and portable electric and hydraulic solutions that are ideal for evaluating the vehicle dynamics of prototypes at the proving ground or tuning racecar dampers at the track.
MTS damper performance solutions employ high precision encoders (electric systems) or velocity preservation compensators (servohydraulic systems) to track command signals with very low distortion.
Easy, Intuitive Use
MTS damper testing software is designed for ease-of-use, featuring wizard-based guides for test creation and execution and Excel-based macros for easy analysis and reporting.
Versatile
Performance damper test system can generate a full spectrum of waveforms, including sinusoidal, triangle, square, sine-on-sine, variable sine, random and frequency sweep.
Innovative Technology
The EMA product line combines the latest linear electric actuator technology and high-performance FlexTest controls to deliver superior performance and highly precise results.
Model Comparison
SYD Systems (Crank Dynos)
Performance Characterization (Sinusoidal)
5.0 -20.0 kN
Rotary Servoelectric Actuation (Scotch Yoke Dyno)
Shock 6 Software
EMA Systems
Performance Characterization (Programmable)
8.9 – 26.7 kN
Linear Electro-Magnetic Actuation
Shock 6 (Standard) or MTS Damper Software
Featured Case Studies
Technical Overview
Units
EMA-2K
EMA-4K
EMA-6K
Dynamic Force
kN
8.9
17.8
26.7
lbf
2000
4000
6000
Static Force
kN
2.1
4.2
6.2
lbf
475
950
1400
Static Force with Static Load Compensation
>kN
7
13
20
lbf
1475
2950
4400
Peak Velocity
m/sec
4
4
4
in/sec
157
157
157
Velocity at Peak Force
m/sec
2.5
2.5
2.5
in/sec
98
98
98
Stroke
mm
203
203
203
in
8
8
8
Frequency Response
Hz
100
100
100
Temperature Monitoring
Specimen
Non-contacting IR with software monitoring
Motor
Non-contacting IR with process meter monitoring
Digital Encoder Accuracy
μ
1
1
1
Noise Level – Typical
dbA
<60
<60
<60
Load Cell
lbf
2000
5000
10000
Type
Interface
Waveforms Supported
Type
Sine, Triangle, Square, Frequency Sweep, Custom Profile
Software
SHOCK™ Test Control and Damper Analysis Software
Bearing Material
Type
Dry Linear Bearing – Maintenance Free Replacement Interval: 2-5 yrs
Facility Requirements1
V
220
220
220
A
30
60
100
Air Supply
PSI
100
100
100
BAR
7
7
7
CFM
35
35
35
Specifications subject to change