Acumen® Electrodynamic Test Systems
With force capacities up to 12kN or down to milli-Newtons, these clean and quiet systems can extend energy-efficient electrodynamic testing to many applications. The system's intuitive visual displays and software graphics simplify test setup, monitoring and modification, and the sturdy design delivers high precision and accuracy.
Applications
- Analisi di meccanica dinamica (DMA)
- Tensione
- Torsione
- Test a bassa forza
- Test di fatica
- Qualificazione dinamica
- Compressione
- Piegatura
- Flettere
Test Specimens
-
Polimeri
- Materiali elastomerici
- Elastomeri
- Materie plastiche
- Polimeri
- Gomma
- Biomateriali e dispositivi medici
-
Materiali compositi
- Fibra di carbonio
- Matrice ceramica
- Materiali compositi
- Matrice metallica
- Matrice polimerica
- Ceramica
- Prodotti di consumo e imballaggio
- Microelettronica
Test Standards
- ISO 14801
- ISO 6475
- ASTM F1717
- ASTM F2077
- ISO 7206
- ASTM 1440
- ASTM F543
- ASTM F1800
- ISO 14879
- ASTM F3140-17
- ASTM D7028
- ASTM D5992
- ASTM D5023
- ASTM D5024
- ASTM D5026
- ASTM D5418
- ISO 6721-4
- ISO 6721-5
- ISO 1099
- ASTM 466-96
- ASTM 468-90
- ASTM E606
- ASTM D3479
- ASTM E466
- ASTM E2368
- EUR 22281 EN
- ASTM E647
- ASTM E399
- ASTM E1820
- ASTM 399-17
- ISO 6892
- ASTM D412
- ASTM D882
- ASTM 527-2
- ASTM 527-3
- ISO 7800
- ASTM A938
- ASTM D1043
- ASTM D5279
- ASTM F383
- ISO 5835
- ISO 9268
- ISO 80369-1
- ISO 6721-12
Key Product Features
Easy, Intuitive Use
Simple installation, setup, test monitoring and modification
Accurate / Repeatable Results
Patent-pending software algorithms provide auto-tuning
Energy Efficient
Electric actuation uses less energy
Innovative Technology
Industry-leading performance, with up to 12 kN force capacity and axial/torsional options
Model Comparison
Acumen 1
- Dynamic force: 1250 N (281 (lbf)
- Static force: 850 N (191 lbf)
- Actuator dynamic stroke: 70 mm (2.75 in)
- Tabletop
Acumen 3
- Dynamic force: 3000 N (670 lbf)
- Static force: 2000 N (450 lbf)
- Actuator dynamic stroke: 70 mm (2.75 in)
- Dynamic torque rating: +/- 30 Nm (265 in-lb)
- Static torque rating: +/- 21 Nm (185 in-lb)
- Tabletop
- Available in standard or axial/torsional configurations
Acumen 12
- Dynamic force: 12000 N (2697 lbf)
- Static force: 8500 N (1910 lbf)
- Actuator dynamic stroke: 70 mm (2.75 in)
- Dynamic torque rating: +/-120 Nm (1056 in-lb)
- Static torque rating: +/- 84.8 Nm (746 in-lb)
- Floor-standing
- Available in standard or axial/torsional configurations
Featured Case Studies
Full Product Information
Acumen 1 Specifications
|
|
DIAGRAM |
MODEL |
|
LOAD FRAME SPECIFICATIONS1 |
DETAIL |
ACUMEN 1 |
|
Dynamic force² |
|
1250 N (281 lbf) |
|
Static force² |
|
850 N (191 lbf) |
|
Actuator dynamic stroke |
|
70 mm (2.75 in) |
|
Angular displacement |
|
– |
|
Dynamic performance |
|
≤100 Hz |
|
Minimum test space height³ |
A |
26 mm (1.02 in) |
|
Maximum test space height⁴ |
A |
603 mm (23.74 in) |
|
Working height⁵ |
B |
133 mm (5.24 in) |
|
Test space width |
|
|
|
(measured between columns) |
C |
375 mm (14.76 in) |
|
Base plate design |
|
T-Slot |
|
|
|
(industry standard: 8 mm) |
|
Column diameter |
D |
63.5 mm (2.5 in) |
|
Frame footprint width |
E |
550 mm (21.62 in) |
|
Frame footprint depth⁶ |
F |
485 mm (19.09 in) |
|
Overall width⁶ |
|
|
|
(with frame-mounted controller) |
G |
679 mm (26.73 in) |
|
Overall height⁷ |
H |
1511 mm (59.49 in) |
|
Weight |
|
159 kg (350 lb) |
|
Noise level - typical⁸ |
|
47 dbA |
|
Noise level - maximum⁸ |
|
69 dbA |
|
Mounting |
|
Tabletop: Vertical |
|
Standard load cell |
|
1.5 kN Accel Comp |
|
Operating temperature |
|
+5C° to +40C° |
|
Cooling |
|
Automated forced air |
|
Electrical requirements⁹ |
Voltage - VAC |
100-120 (200-240) |
|
|
Frequency - Hz |
50 - 60 |
|
|
Current - Amps |
7 (4) |
|
|
Phase |
Single |

Acumen 3 and 12 Specifications
|
|
DIAGRAM |
MODEL |
|
|
|
|
LOAD FRAME SPECIFICATIONS1 |
DETAIL |
ACUMEN 3 |
ACUMEN 3 A/T |
ACUMEN 12 |
ACUMEN 12 A/T |
|
Dynamic force² |
|
3000 N (670 lbf) |
3000 N (670 lbf) |
12000 N (2697 lbf) |
12000 N (2697 lbf) |
|
Static force² |
|
2000 N (450 lbf) |
2000 N (450 lbf) |
8500 N (1910 lbf) |
8500 N (1910 lbf) |
|
Dynamic torque rating |
|
– |
±30 Nm (265 in-lb) |
– |
±120 Nm (1056 in-lb) |
|
Static torque rating |
|
– |
±21 Nm (185 in-lb) |
– |
±84.8 Nm (746 in-lb) |
|
Actuator dynamic stroke |
|
70 mm (2.75 in) |
70 mm (2.75 in) |
70 mm (2.75 in) |
70 mm (2.75 in) |
|
Angular displacement |
|
– |
±135° |
– |
±135° |
|
|
|
|
±20 revolutions |
|
±20 revolutions |
|
|
|
|
0.001 rpm - 100 rpm |
|
0.001 rpm - 100 rpm |
|
|
|
|
continuous rotation |
|
continuous rotation |
|
|
|
|
to 350 rpm |
|
to 100 rpm |
|
Dynamic performance |
|
≤100 Hz |
≤100 Hz |
≤100 Hz |
≤100 Hz |
|
Minimum test space height³ |
A |
26 mm (1.02 in) |
0 mm (0.00 in) |
55 mm (2.17 in) |
0 mm (0.00 in) |
|
Maximum test space height⁴ |
A |
819 mm (32.24 in) |
603 mm (23.74 in) |
985 mm (38.8 in) |
810 mm (31.9 in) |
|
Working height⁵ |
B |
133 mm (5.24 in) |
133 mm (5.24 in) |
815 mm (32.1 in) |
815 mm (32.1 in) |
|
Test space width |
C |
460 mm (18.11 in ) |
460 mm (18.11 in ) |
460 mm (18.11 in ) |
460 mm (18.11 in ) |
|
(measured between columns) |
|
|
|
|
|
|
Base plate design |
|
T-Slot |
T-Slot |
T-Slot |
T-Slot |
|
|
|
(industry standard: 8 mm) |
(industry standard: 8 mm) |
(industry standard: 14mm) |
(industry standard: 14 mm) |
|
Column diameter |
D |
63.5 mm (2.5 in) |
63.5 mm (2.5 in) |
76.2 mm (3 in) |
76.2 mm (3 in) |
|
Frame footprint width |
E |
634 mm (24.96 in) |
634 mm (24.96 in) |
651 mm (25.6 in) |
651 mm (25.6 in) |
|
Frame footprint depth⁶ |
F |
501 mm (19.72 in) |
501 mm (19.72 in) |
817 mm (32.2 in) |
817 mm (32.2 in) |
|
Overall width⁶ |
G |
764 mm (30.08 in) |
764 mm (30.08 in) |
805 mm (31.7 in) |
805 mm (31.7 in) |
|
(with frame-mounted controller) |
|
|
|
|
|
|
Overall height⁷ |
H |
1726 mm (67.95 in) |
1726 mm (67.95 in) |
2810 mm (110.7 in) |
2810 mm (110.7 in) |
|
Weight |
|
188 kg (415 lb) |
230 kg (507 lb) |
953 kg (2100 lb) |
1043 kg (2300 lb) |
|
Noise level - typical⁸ |
|
47 dbA |
47 dbA |
62 |
62 |
|
Noise level - maximum⁸ |
|
69 dbA |
69 dbA |
78 |
78 |
|
Mounting |
|
Tabletop: Vertical |
Tabletop: Vertical |
Floor: Vertical |
Floor: Vertical |
|
Standard load cell |
|
3 kN Accel Comp |
3 kN Accel Comp |
12 kN Accel Comp |
12 kN Accel Comp |
|
Operating temperature |
|
+5C° to +40C° |
+5C° to +40C° |
+5C° to +40C° |
+5C° to +40C° |
|
Cooling |
|
Automated forced air |
Automated forced air |
Automated forced |
Automated forced |
|
|
|
|
|
air & self contained |
air & self contained |
|
|
|
|
|
water cooled |
water cooled |
|
Electrical requirements⁹ |
Voltage - VAC |
200-240 |
200-240 |
200-240 |
200-240 |
|
|
Frequency - Hz |
50 - 60 |
50 - 60 |
50 - 60 |
50 - 60 |
|
|
Current - Amps |
10 |
20 |
38 |
38 |
|
|
Phase |
Single |
Single |
Single |
Single |
|
|
|
|
|
|
|
|
1.Specifications subject to change without notice. |
|
|
|
||
|
2.Verifiable with MTS compression spring test. Performance may vary depending on test type, test set-up, frequency, specimen, environment and other factors. |
|||||
|
3.Assumes standard system load cell installed, crosshead fully lowered and actuator fully extended to end of the dynamic stroke. |
|||||
|
4.Assumes standard system load cell installed, crosshead fully raised and actuator fully retracted to end of the dynamic stroke. |
|||||
|
5.From table to top of work surface; without optional isolation pads. |
|
|
|
||
|
6.For systems with optional test area enclosure, add 98 mm (3.8 in.) to dimension F and 45 mm (1.8 in) to dimension G for overall system dimensions. |
|||||
|
7.Measured with crosshead fully raised, without optional isolation pad. |
|
|
|
||
|
8.Typical usage at 1 m, free field. Noise level varies depending upon test type, specimen, environment and other factors. |
|
||||
|
9.Acumen 1 current rated at 100 (200) VAC. Acumen 3 current rated at 200 VAC. |
|
|
|||
Supporting the mission of biomedical researchers and manufacturers
Key options for biomedical testing:
- 12 kN force capacity
- Conducts orthopaedic studies to 4x body weight
- Additional axial/torsional capability
- Higher speeds, higher torque and more continuous rotation to test a wider range of materials
- Precise low-force measurement
- Easily tests fragile, intricate or lightweight specimen
- Multi-sample fatigue fixture
- Triggers independent data acquisition for 15 samples at once
Use MTS Acumen systems to test:
- Orthopaedic constructs: small joints, c-spine, finger, ankle
- Trauma devices: plates, screws, constucts
- Biomaterials: plastics, soft tissues, hydrogels, ligaments, bones
- Dental materials/devices: cements, plastics, metals
- Vascular devices: stents, grafts
- Packaging and consumables: needles, syringes, packaging, tubing
GET THE MOST OUT OF YOUR INVESTMENT
Our experts are here to help keep you up and running.
Related Products, Parts or Accessories
Series 651 Environmental Chambers
Multi-Sample Fatigue Fixture
Acumen Load Cells With Built-in Accelerometers
Axial Extensometers with 25 mm (1 in.) Gage Length
Landmark® Servohydraulic Test Systems
TestSuite Software
Looking for more products?
Go to Solution FinderResources
Electric Actuation for Low Force Applications
MTS application engineers discuss advantages of electric act…
Test di piegatura a 4 punti
Guarda la demo su piccola scala del test di piegatura a 4 pu…
Electrodynamic Excellence
MTS Acumen test systems offer advantages in system control, …
Ambito di applicazione mutevole di DMA
Gli ingegneri MTS discutono delle ultime novità nell'analisi…
Nuovo estensimetro ottico
Controllo e misurazione semplificati senza contatto della de…
Monitoraggio della frattura di molteplici campioni contemporaneamente
Tecniche per accelerare il test sui dispositivi endovascolar…
Diminuzione del tempo di test per i dispositivi in nitinol
Esame della durata a fatica delle leghe di nichel titanio ut…
Uso della DMA per la caratterizzazione di materiali
Elastomeri, polimeri e leghe a memoria di forma: MTS aiuta i…